{"id":59898,"date":"2024-10-08T03:32:58","date_gmt":"2024-10-08T03:32:58","guid":{"rendered":"https:\/\/www.fooddiagnostics.dk\/vare\/ridaquick-gluten-quant\/"},"modified":"2024-10-08T03:32:58","modified_gmt":"2024-10-08T03:32:58","slug":"ridaquick-gluten-quant","status":"publish","type":"product","link":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/","title":{"rendered":"RIDA\u00aeQUICK Gluten quant"},"content":{"rendered":"<h1><strong>RIDA\u00aeQUICK Gluten quant &#8211; Quantification of gluten in food and surfaces<\/strong><\/h1>\n<p>RIDA\u00aeQUICK Gluten quant is an innovative kit that allows you to quantify the amount of prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from both swab samples, CIP water and food samples, using an android mobile or a RIDA\u00aeSMART BOX. No cross-reaction detected in 107 tested foods.  <\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<ul>\n<li><strong>LoD:<\/strong><\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Swab: 0.038 \u00b5g\/mL gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>CIP water: 0.072 \u00b5g\/mL gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Food samples: 0.510 mg\/kg gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li><strong>LoQ:<\/strong><\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Swab: 0.20 \u00b5g\/mL gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>CIP water: 0.25 \u00b5g\/mL gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Food samples: 3 mg\/kg gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li><strong>Measurement range:<\/strong><\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Swab: 0.20 &#8211; 4 \u00b5g\/mL gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>CIP water: 0.20 &#8211; 4 \u00b5g\/mL gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Food samples: 2 &#8211; 40 mg\/kg gluten<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>The kit contains strips and liquids for 15 tests. The kit is validated on baked goods, sauces, chocolate-containing desserts, spices and rice flour. Also validated on stainless steel surfaces and CIP water.  <\/p>\n<p><strong>Advantages:<\/strong><\/p>\n<ul>\n<li>Based on R5 antibody: Comparability of results with our other gluten test systems.<\/li>\n<li>Simple extraction procedure using extraction tablet.<\/li>\n<li>Rapid analysis: Ensures quantitative results within 30 minutes (ELISA) or 10 minutes (LFD).<\/li>\n<li>Improved calibration and validation: Use of matrices contaminated with wheat, rye and barley, in accordance with the latest AOAC guidelines.<\/li>\n<li>No conversion needed anymore: Quantitative analysis of gluten residues from wheat, rye and barley due to calibration against gluten (not gliadin!).<\/li>\n<li>Ready-to-use reagents that are long-lasting and simplify the testing process.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p><b><span data-contrast=\"auto\">RIDA\u00aeQUICK Gluten quant <\/span><\/b><span data-contrast=\"auto\">is an innovative kit that allows you to quantify the amount of prolamins from both swab samples, CIP water and food samples.<\/span><\/p>\n","protected":false},"featured_media":49746,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[13254,13253,13304,13309],"product_tag":[],"class_list":["post-59898","product","type-product","status-publish","has-post-thumbnail","product_cat-biochemistry-allergens","product_cat-biochemistry","product_cat-biochemistry-allergens-gluten","product_cat-biochemistry-allergens-gluten-lateral-flow","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>RIDA\u00aeQUICK Gluten quant - Food Diagnostics<\/title>\n<meta name=\"description\" content=\"Lateral Flow kit for quantifying prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from swab samples, CIP water and food samples,\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RIDA\u00aeQUICK Gluten quant - Food Diagnostics\" \/>\n<meta property=\"og:description\" content=\"Lateral Flow kit for quantifying prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from swab samples, CIP water and food samples,\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/\" \/>\n<meta property=\"og:site_name\" content=\"Food Diagnostics\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/RAL7073-2.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/\",\"url\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/\",\"name\":\"RIDA\u00aeQUICK Gluten quant - Food Diagnostics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/wp-content\\\/uploads\\\/RAL7073-2.webp\",\"datePublished\":\"2024-10-08T03:32:58+00:00\",\"description\":\"Lateral Flow kit for quantifying prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from swab samples, CIP water and food samples,\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/wp-content\\\/uploads\\\/RAL7073-2.webp\",\"contentUrl\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/wp-content\\\/uploads\\\/RAL7073-2.webp\",\"width\":800,\"height\":800,\"caption\":\"RIDA\u00aeQUICK Gluten quant\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/vare\\\/ridaquick-gluten-quant\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Hjem\",\"item\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/food-diagnostics\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"RIDA\u00aeQUICK Gluten quant\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/\",\"name\":\"Food Diagnostics\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/#organization\",\"name\":\"Food Diagnostics\",\"url\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/wp-content\\\/uploads\\\/cropped-FD_Logo_Hexagon-1.png\",\"contentUrl\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/wp-content\\\/uploads\\\/cropped-FD_Logo_Hexagon-1.png\",\"width\":512,\"height\":512,\"caption\":\"Food Diagnostics\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fooddiagnostics.dk\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RIDA\u00aeQUICK Gluten quant - Food Diagnostics","description":"Lateral Flow kit for quantifying prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from swab samples, CIP water and food samples,","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/","og_locale":"en_US","og_type":"article","og_title":"RIDA\u00aeQUICK Gluten quant - Food Diagnostics","og_description":"Lateral Flow kit for quantifying prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from swab samples, CIP water and food samples,","og_url":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/","og_site_name":"Food Diagnostics","og_image":[{"width":800,"height":800,"url":"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/RAL7073-2.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/","url":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/","name":"RIDA\u00aeQUICK Gluten quant - Food Diagnostics","isPartOf":{"@id":"https:\/\/www.fooddiagnostics.dk\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/#primaryimage"},"image":{"@id":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/#primaryimage"},"thumbnailUrl":"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/RAL7073-2.webp","datePublished":"2024-10-08T03:32:58+00:00","description":"Lateral Flow kit for quantifying prolamins from wheat (gliadins), rye (secalins) and barley (hordeins) from swab samples, CIP water and food samples,","breadcrumb":{"@id":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/#primaryimage","url":"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/RAL7073-2.webp","contentUrl":"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/RAL7073-2.webp","width":800,"height":800,"caption":"RIDA\u00aeQUICK Gluten quant"},{"@type":"BreadcrumbList","@id":"https:\/\/www.fooddiagnostics.dk\/en\/vare\/ridaquick-gluten-quant\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Hjem","item":"https:\/\/www.fooddiagnostics.dk\/en\/food-diagnostics\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/www.fooddiagnostics.dk\/shop\/"},{"@type":"ListItem","position":3,"name":"RIDA\u00aeQUICK Gluten quant"}]},{"@type":"WebSite","@id":"https:\/\/www.fooddiagnostics.dk\/en\/#website","url":"https:\/\/www.fooddiagnostics.dk\/en\/","name":"Food Diagnostics","description":"","publisher":{"@id":"https:\/\/www.fooddiagnostics.dk\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fooddiagnostics.dk\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fooddiagnostics.dk\/en\/#organization","name":"Food Diagnostics","url":"https:\/\/www.fooddiagnostics.dk\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fooddiagnostics.dk\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/cropped-FD_Logo_Hexagon-1.png","contentUrl":"https:\/\/www.fooddiagnostics.dk\/wp-content\/uploads\/cropped-FD_Logo_Hexagon-1.png","width":512,"height":512,"caption":"Food Diagnostics"},"image":{"@id":"https:\/\/www.fooddiagnostics.dk\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/product\/59898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/product\/59898\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/media\/49746"}],"wp:attachment":[{"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/media?parent=59898"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/product_brand?post=59898"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/product_cat?post=59898"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fooddiagnostics.dk\/en\/wp-json\/wp\/v2\/product_tag?post=59898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}